Field Testing & Twin SaaS
🇬🇧 Full UI + PDF + National Standard Mapping: UI + PDF in English. Normative references follow international IEC 60364, BS 7671:2018+A2:2022, IEEE, and NFPA 70E/70B.

About OhmCert

Built by Field Engineers, for Mission-Critical Compliance.

OhmCert eliminates the gap between complex international standards (IEC, NFPA, IEEE, ISO) and field electrical verification.

The Problem

Traditional electrical certification still relies on disconnected spreadsheets, hand-written notes, and manual calculations performed back in the office. By the time a report is issued, the link between the field measurement and the standard it must satisfy has often been broken. Errors propagate, traceability weakens, and critical safety margins are missed.

Engineering Philosophy

OhmCert embeds real-time mathematical validation directly at the point of measurement. BS 7671 thermal corrections, IEEE 43 PI/DAR curves, ANSI/TIA-942 verification logic and ISO 50001 energy review rules are applied the moment a value is entered, so engineers leave the site with a defensible, signed certificate instead of a stack of paper.

IBC

Irfan Batu Cinar

Founder & Lead Systems Architect, OhmCert

  • BSc. Electrical Engineering (ITU)
  • MBA
  • Certified Energy Manager (CEM)
  • Lean Six Sigma Black Belt

Irfan is a BSc. Electrical Engineer from Istanbul Technical University with an MBA, Certified Energy Manager (CEM) and Lean Six Sigma Black Belt credentials. He brings 15+ years of hands-on industrial electrical engineering and energy management leadership, including serving as Electrical Maintenance Unit Manager at one of Türkiye's premier flat-steel manufacturing complexes (a joint-venture mill of one of the world's largest steelmakers). In that role he managed 93.5 MVA of high-voltage power distribution, 37 power and distribution transformers, SCADA energy monitoring, and ISO 50001 / ISO 45001 compliance for facilities consuming more than 160 million kWh annually.

His areas of expertise include HV/MV/LV substation distribution, power transformers & Buchholz protection, variable speed drives, earth fault loop impedance, harmonic mitigation under IEEE 519, and mission-critical backup systems. OhmCert was built from that field experience to close the loop between standards and practice.

Connect on LinkedIn

Engineering Standards & Rigor Matrix

OhmCert modules are referenced to the exact clauses and limits inspectors are audited against.

IEC 60364-6 / BS 7671

Low-voltage electrical installations, earthing, loop impedance and disconnection times.

NFPA 70B / 70E

Electrical maintenance programmes, condition of maintenance and arc flash PPE boundaries.

IEEE 43 & 1100 Emerald Book

Insulation resistance, polarization index and neutral-to-earth power quality in IT environments.

ANSI/TIA-942 Tier III/IV

Data center redundancy proof, ATS/STS transfer, grounding and PDU phase balance.

ISO 50001:2018

Energy reviews, significant energy uses, baselines and EnPI normalisation.

IEC 62305 / EN 62305

Lightning protection system component inspection and earth termination resistance.

ENGINEERING SUITE

OhmCert & projelk

See the platform in action

Start with 5 free inspection runs this month and generate your first official OhmCert report.